Star-delta starter

COMPOSITION:

  • Metal sheet cabinet or box, RAL 7035
  • Door interlock switch disconnector
  • Main fuses
  • 3 contactors
  • Thermal relay
  • Voltmeter
  • Ammeter
  • Current transformer (starting from AST-L 20/40)
  • Voltmeter selector switch (starting from AST-L 20/40)
  • 400/24 V safety transformer for auxiliary circuit
  • Protection fuses for transformer and auxiliary circuit
  • Green warning light (run)
  • Red warning light (overload)
  • AUT-0-MAN selector switch
  • Start-stop push buttons
  • Delayed star-delta relay
  • Delayed start-up relay
  • Terminal board (motor output, arrangement for float or pressure switch)
  • 4 fixing brackets
  • Instruction manual

    TECHNICAL FEATURES:
  • Power supply voltage 400 Vac ±10%
  • Operating frequency 50/60 Hz
  • Protection degree IP55
  • Operating temperature -5/+40°C

PRODUCTS TYPOLOGY

STAR-DELTA STARTERS

CATEGORY OF USE

AGRICULTURE

TECHNOLOGY

ELECTRO-MECHANICAL

CABINET MATERIAL

METAL SHEET

CAPACITOR

NO

IGNITION TYPOLOGY

START-STOP PUSH BUTTONS
AUT-O-MAN SELECTOR SWITCH

METERS

VOLTMETER AND AMMETER

PROTECTION

THERMAL RELAY

DOOR INTERLOCK SWITCH DISCONNECTOR

YES

PHASES

400V THREE PHASE – 400V THREE PHASE

NO. ENGINES

1

DISPLAY

NO

DRY RUNNING CONTROL

NO

PRESSURE TRANSDUCER

NO

POWERS (HP)

10
12,5
15
17,5
20
25
30
35
40
50
60
70
75
80
90
100
125
150
180
200
220
250
300

WIRED ACCESSORIES (OPTIONAL)

WATER LEVEL ELECTROPROBE, ELSOND-B TYPE + 3 TERMINALS
WATER LEVEL ELECTROPROBE, ELSOND-SV TYPE + 3 TERMINALS
WATER LEVEL ELECTROPROBE, ELSOND-RSV TYPE + 3 TERMINALS
PHASES FAILURE – SEQUENCE - UNBALANCE RELAY, PCF38 TYPE
DAILY ANALOG TIMER WITH BATTERY
DAILY ANALOG TIMER WITHOUT BATTERY
WEEKLY DIGITAL TIMER
HOUR METER
SAUT-O-MAN KEY SELECTOR SWITCH
TIMER RELAY
AMMETER SELECTOR SWITCH + 3 CURRENT TRANSFORMERS
ALARM CIRCUIT WITH FLASHING SIREN
ALARM CIRCUIT WITH FLASHING SIREN AND BACKUP BATTERY
THERMISTOR CONNECTION CIRCUIT WITH WARNING LIGHT AND 2 AUXILIARY TERMINALS
CIRCUIT FOR CONDUCTIVITY PROBE CONNECTION WITH WARNING LIGHT AND 2 AUXILIARY TERMINALS
SEWAGE WATER KIT WITH RELAY AND 4 AUXILIARY TERMINALS
STATUS SIGNAL RELAY WITH 3 AUXILIARY TERMINALS
4 STATUS SIGNAL RELAYS FOR PUMPS REMOTE CONTROL WITH 16 AUXILIARY TERMINALS
IRRIGATION KIT
DIGITAL VOLTMETER WITH MIN/MAX VOLTAGE ALARM SIGNAL
DIGITAL AMMETER WITH MIN/MAX CURRENT ALARM SIGNAL
REMOTE CONTROL WITH ANTENNA AND REMOTE CONTROL DEVICE, MAX 150 M
REMOTE CONTROL WITH ANTENNA AND REMOTE CONTROL DEVICE, MAX 700 M
REMOTE CONTROL WITH COMPLETE GSM MODULE – SMS COMMAND BY MOBILE PHONE
COSΦ CONTROL RELAY WITH CURRENT TRANSFORMER
MIN/MAX VOLTAGE RELAY / PHASES FAILURE – SEQUENCE - UNBALANCE