0039 095 798 18 69
floridia@floridia.it
Paterno' (CT)
AS-BY-D
  • AS-BY-D
  • AS-BY-D

AS-BY-D

Soft starter with by-pass concactor and digital control key-pad

COMPOSITION:

  • Metal sheet box, RAL 7035
  • Door interlock switch disconnector
  • Main fuses
  • Soft starter with by-pass contactor
  • Contactor
  • Digital control keypad “Multi-D” with LCD panel card
  • 3 current transformers
  • 400/24 V safety transformer for auxiliary circuit
  • Protective fuses for transformer and auxiliary circuit
  • Forced ventilation (starting from AS-BY-D 40/40)
  • Action programming
  • Terminal board (motor output, arrangement for float or pressure switch)
  • 4 fixing brackets
  • Instruction manual

TECHNICAL FEATURES:

  • Power supply voltage 400 Vac ±10%
  • Operating frequency 50/60 Hz
  • Protection degree IP55
  • Operating temperature -5/+40°C
  • Very low voltage input for emergency pressure switch (clear contact)
  • Very low voltage input for electric probe or float (clear contact)
  • Button for the Automatic-O-Manual operation
  • Buttons for parameters settings
  • Backlighted display for viewing of:
    - Main voltage;
    - Motor current;
    - Motor power;
    - Alarms;
    - All messages related to motor operation;
    - Multilanguage: Italian, English, Spanish, German, French

PROTECTIONS:

  • Min/max voltage
  • Max current
  • Phase/s absence and unbalance (current)
  • Phases (voltage) sequence
  • Protective fuse for electronic card circuit
  • Dry run through min current

SETTINGS AND CONTROLS:

  • Language
  • Mains return delay
  • Min voltage
  • Max voltage
  • Max current
  • Phases unbalance
  • Phases sequence
  • Min current
  • Thermal delay
  • Contactors exchange time
  • Automatic recovery mode
  • Autoconfiguration

PRODUCTS TYPOLOGY

STARTERS WITH SOFT START

CATEGORY OF USE

AGRICULTURE

TECHNOLOGY

ELECTRO-MECHANICAL

CABINET MATERIAL

METAL SHEET

CAPACITOR

NO

IGNITION TYPOLOGY

START-STOP PUSH BUTTONS
AUT-O-MAN PUSH BUTTONS

METERS

DIGITAL INSTRUMENT

PROTECTION

ELECTRONIC CARD

DOOR INTERLOCK SWITCH DISCONNECTOR

YES

PHASES

400V THREE PHASE – 400V THREE PHASE

NO. ENGINES

1

DISPLAY

LCD SCREEN

DRY RUNNING CONTROL

DRY RUNNING CONTROL WITH MINIMUM CURRENT

PRESSURE TRANSDUCER

NO

POWERS (HP)

3
4
5
5,5
7,5
10
12,5
15
17,5
20
25
30
35
40
50
60
80
100
125
150

WIRED ACCESSORIES (OPTIONAL)

WATER LEVEL ELECTROPROBE, ELSOND-B TYPE + 3 TERMINALS
WATER LEVEL ELECTROPROBE, ELSOND-SV TYPE + 3 TERMINALS
WATER LEVEL ELECTROPROBE, ELSOND-RSV TYPE + 3 TERMINALS
DAILY ANALOG TIMER WITH BATTERY
DAILY ANALOG TIMER WITHOUT BATTERY
WEEKLY DIGITAL TIMER
HOUR METER
START-STOP PUSH BUTTONS
SAUT-O-MAN KEY SELECTOR SWITCH
TIMER RELAY
VOLTMETER
AMMETER
CURRENT TRANSFORMER
FREQUENCY COUNTER
VOLTMETER SELECTOR SWITCH + 3 FUSES
AMMETER SELECTOR SWITCH + 3 CURRENT TRANSFORMERS
ALARM CIRCUIT WITH FLASHING SIREN
ALARM CIRCUIT WITH FLASHING SIREN AND BACKUP BATTERY
THERMISTOR CONNECTION CIRCUIT WITH WARNING LIGHT AND 2 AUXILIARY TERMINALS
CIRCUIT FOR CONDUCTIVITY PROBE CONNECTION WITH WARNING LIGHT AND 2 AUXILIARY TERMINALS
STATUS SIGNAL RELAY WITH 3 AUXILIARY TERMINALS
4 STATUS SIGNAL RELAYS FOR PUMPS REMOTE CONTROL WITH 16 AUXILIARY TERMINALS
IRRIGATION KIT
REMOTE CONTROL WITH ANTENNA AND REMOTE CONTROL DEVICE, MAX 150 M
REMOTE CONTROL WITH ANTENNA AND REMOTE CONTROL DEVICE, MAX 700 M
REMOTE CONTROL WITH COMPLETE GSM MODULE – SMS COMMAND BY MOBILE PHONE