0039 095 798 18 69
floridia@floridia.it
Paterno' (CT)
ADE 4-20
  • ADE 4-20
  • ADE 4-20

ADE 4-20

Three-phase electronic direct starter with 4÷20 mA control

COMPOSITION:

  • ABS box (type V0)
  • Door interlock switch disconnector
  • Mother board
  • LCD panel card
  • Fuses
  • Contactor
  • Cable clamps
  • Instruction manual
  • Pressure transducer 4÷20 mA included

TECHNICAL FEATURES:

  • Power supply voltage 400 Vac ±10%
  • Operating frequency 50/60 Hz
  • Protection degree IP55
  • Operation temperature -5/+40°C
  • Very low voltage input for pressure switch or float switch (clear contact)
  • Pressure transducer input (4÷20 mA)
  • Button for the Automatic-O-Manual operation
  • Buttons for parameters settings
  • Liquid crystal display for viewing of:
    - Mains voltage;
    - Motor current;
    - Motor power;
    - Pressure;
    - Alarms;
    - All messages related to motor operation;
    - Multilanguage: Italian, English, Spanish, German, French

PROTECTIONS:

  • Minimum/maximum voltage
  • Motor alarm return delay (fixed time)
  • Maximum current
  • Absence of phase/s current
  • Phase sequence and unbalance
  • Dry run through pressure transducer
  • Protective fuse/s for power circuit
  • Protective fuse for electronic card circuit

SETTINGS AND CONTROLS:

  • Language
  • Mains return delay
  • Minimum voltage
  • Maximum voltage
  • Minimum/maximum current
  • Phases unbalance
  • Thermal delay
  • Sensor pressure
  • Max pressure
  • Min pressure
  • Min pressure delay
  • Max pressure delay
  • Automatic recovery mode
  • Autoconfiguration

PRODUCTS TYPOLOGY

ELECTRONIC DIRECT STARTERS

CATEGORY OF USE

AGRICULTURE
CIVIL USE

TECHNOLOGY

ELECTRONIC

CABINET MATERIAL

ABS

CAPACITOR

NO

IGNITION TYPOLOGY

START-STOP PUSH BUTTONS
AUT-O-MAN PUSH BUTTONS

METERS

DIGITAL INSTRUMENT

PROTECTION

ELECTRONIC CARD

DOOR INTERLOCK SWITCH DISCONNECTOR

YES

PHASES

400V THREE PHASE – 400V THREE PHASE

NO. ENGINES

1

DISPLAY

LCD SCREEN

DRY RUNNING CONTROL

DRY RUNNING CONTROL WITH MINIMUM CURRENT

PRESSURE TRANSDUCER

YES

POWERS (HP)

0,5
0,75
1
1,5
2
3
4
5
5,5
7,5
10
12,5
15
17,5
20

WIRED ACCESSORIES (OPTIONAL)

ALARM CIRCUIT WITH FLASHING SIREN