0039 095 798 18 69
floridia@floridia.it
Paterno' (CT)
AD-ABS-VA
  • AD-ABS-VA
  • AD-ABS-VA

AD-ABS-VA

Three-phase direct starter with voltmeter and ammeter

COMPOSITION:

  • ABS box (type V0)
  • Door interlock switch disconnector
  • Main fuses
  • Contactor
  • Thermal relay
  • Voltmeter 72x72 mm
  • Ammeter 72x72 mm
  • 400-230/24V safety transformer for auxiliary circuit
  • Current transformer (only for 20 Hp version)
  • Protective fuse for auxiliary circuit
  • Green warning light (run)
  • Red warning light (overload)
  • AUT-0-MAN selector switch
  • Terminal board (Motor output, arrangement for float or pressure switch)
  • Cable clamps
  • Fixing brackets
  • Instruction manual

TECHNICAL FEATURES:

  • Power supply voltage 400 Vac ±10%
  • Operating frequency 50/60 Hz
  • Protection degree IP55
  • Operating temperature -5 /+40°C
  • Very low voltage input for pressure switch or float switch (clear contact)

PRODUCTS TYPOLOGY

ELECTRO-MECHANICAL DIRECT STARTERS

CATEGORY OF USE

AGRICULTURE
CIVIL USE

TECHNOLOGY

ELECTRO-MECHANICAL

CABINET MATERIAL

ABS

CAPACITOR

NO

IGNITION TYPOLOGY

AUT-O-MAN SELECTOR SWITCH

METERS

VOLTMETER AND AMMETER

PROTECTION

THERMAL RELAY

DOOR INTERLOCK SWITCH DISCONNECTOR

YES

PHASES

400V THREE PHASE – 400V THREE PHASE

NO. ENGINES

1

DISPLAY

NO

DRY RUNNING CONTROL

NO

PRESSURE TRANSDUCER

NO

POWERS (HP)

0,75
1
1,5
2
3
4
5,5
7,5
10
12,5
15

WIRED ACCESSORIES (OPTIONAL)

WATER LEVEL ELECTROPROBE, ELSOND-B TYPE + 3 TERMINALS
WATER LEVEL ELECTROPROBE, ELSOND-SV TYPE + 3 TERMINALS
WATER LEVEL ELECTROPROBE, ELSOND-RSV TYPE + 3 TERMINALS
PHASES FAILURE – SEQUENCE - UNBALANCE RELAY, PCF38 TYPE
DAILY ANALOG TIMER WITH BATTERY
DAILY ANALOG TIMER WITHOUT BATTERY
WEEKLY DIGITAL TIMER
HOUR METER
START-STOP PUSH BUTTONS
SAUT-O-MAN KEY SELECTOR SWITCH
TIMER RELAY
ALARM CIRCUIT WITH FLASHING SIREN
ALARM CIRCUIT WITH FLASHING SIREN AND BACKUP BATTERY
THERMISTOR CONNECTION CIRCUIT WITH WARNING LIGHT AND 2 AUXILIARY TERMINALS
CIRCUIT FOR CONDUCTIVITY PROBE CONNECTION WITH WARNING LIGHT AND 2 AUXILIARY TERMINALS
SEWAGE WATER KIT WITH RELAY AND 4 AUXILIARY TERMINALS
STATUS SIGNAL RELAY WITH 3 AUXILIARY TERMINALS
4 STATUS SIGNAL RELAYS FOR PUMPS REMOTE CONTROL WITH 16 AUXILIARY TERMINALS
IRRIGATION KIT
REMOTE CONTROL WITH ANTENNA AND REMOTE CONTROL DEVICE, MAX 150 M
REMOTE CONTROL WITH ANTENNA AND REMOTE CONTROL DEVICE, MAX 700 M
REMOTE CONTROL WITH COMPLETE GSM MODULE – SMS COMMAND BY MOBILE PHONE
MIN/MAX VOLTAGE RELAY / PHASES FAILURE – SEQUENCE - UNBALANCE