0039 095 798 18 69
floridia@floridia.it
Paterno' (CT)
ADEM-DE
  • ADEM-DE
  • ADEM-DE

ADEM-DE

Digital single-phase electronic direct starter with LCD panel card

COMPOSITION:

  • ABS box (type V0)
  • Door interlock switch disconnector
  • Main Fuses (Pos. 01 and 02)
  • Circuit breaker (Pos. 03 and 04)
  • Mother board
  • LCD panel card with graphic representation of the switchboard functions
  • Cable clamps
  • Fixing brackets
  • Instruction manual

TECHNICAL FEATURES:

  • Power supply voltage 230 Vac ±10%
  • Operating frequency 50/60 Hz
  • Protection degree IP55
  • Operation temperature -5/+40°C
  • Very low voltage input for pressure switch or float switch

PROTECTIONS:

  • Dry running with minimum current
  • Overload
  • Blocked rotor
  • Max/Min voltage
  • Excessive starts

SETTINGS AND CONTROLS:

  • Dry run delay
  • Dry run reset time
  • Overload reset time
  • Min/Max voltage reset time
  • Motor rated current
  • Motor current for dry run start (%)
  • Motor current for overload (%)
  • Motor current for blocked rotor (%)
  • Min voltage
  • Max voltage
  • Hour meter
  • Water lifting application selection
  • Pressurization application selection
  • Waste water application selection
  • Periodic automatic start for block prevention
  • Auto configuration.

FUNCTIONS:

  • Start button
  • Stop button
  • Button for AUT/MAN mode selection
  • Button for automatic calibration
  • Buzzer
  • LCD display for viewing: mains voltage, motor current, motor status, tank level status, well level status, alarms (of which the last 5 saved in memory), motor operating hours, all the messages related to motor operation.
 

PRODUCTS TYPOLOGY

ELECTRONIC DIRECT STARTERS

CATEGORY OF USE

AGRICULTURE
CIVIL USE
SEWAGE

TECHNOLOGY

ELECTRONIC

CABINET MATERIAL

ABS

CAPACITOR

NO

IGNITION TYPOLOGY

START-STOP PUSH BUTTONS
AUT-O-MAN PUSH BUTTONS

METERS

DIGITAL INSTRUMENT

PROTECTION

ELECTRONIC CARD

DOOR INTERLOCK SWITCH DISCONNECTOR

YES

PHASES

230V SINGLE PHASE – 230V SINGLE PHASE

NO. ENGINES

1

DISPLAY

LCD SCREEN

DRY RUNNING CONTROL

DRY RUNNING CONTROL WITH MINIMUM CURRENT
DRY RUNNING CONTROL THROUGH LEVEL PROBES

PRESSURE TRANSDUCER

NO

POWERS (HP)

0,5
0,75
1
1,5
2
3

WIRED ACCESSORIES (OPTIONAL)

ALARM CIRCUIT WITH FLASHING SIREN