0039 095 798 18 69
floridia@floridia.it
Paterno' (CT)
ADE-RS
  • ADE-RS
  • ADE-RS

ADE-RS

Digital three-phase electronic direct starter with serial port RS-485 and module Wi-Fi managed through APP

COMPOSITION:

  • ABS case (type V0, IP67)
  • Door interlock switch disconnector
  • Mother board
  • LCD panel card
  • Fuses (Pos. 01, 02 and 03)
  • Circuit breaker (Pos. 04 and 05)
  • Contactor
  • Cable clamps
  • Fixing brackets
  • Instruction manual

TECHNICAL FEATURES:

  • Power supply voltage 400 Vac ±10%
  • Operating f requency: 50/60 Hz
  • Protection degree: IP55
  • Operating temperature: -5° / +40°C
  • AUT-0-MAN functions button
  • Start-Stop button
  • Reset button
  • Parameters setting buttons
  • Acoustic alarm (buzzer)
  • LCD display for viewing:
    - Mains voltage;
    - Motor current;
    - Motor cosφ;
    - Motor power;
    - Pressure;
    - Level;
    - Motor status;
    - Digital inputs status;
    - Level probes status;
    - Alarms (of which the last 5 saved in memory);
    - Motor operation hours;
    - All the messages related to the motor operation, 4÷20 mA sensor value;
    - Multilanguage: Italian, English, French, Spanish, German
  • Nr. 2 very low voltage inputs for pressure switches or floats (clear contacts)
  • Nr. 4 inputs for electroprobes + common probe, with adjustable sensitivity from 0 to
  • 50 kΩ (trimmer) with emptying/filling function
  • Input for 4÷20 mA sensor
  • RS-485 for MODBUS-RTU with possible termination
  • Wireless WI-FI module with a dedicated APP for smartphones
  • AUX output for alarms

PROTECTIONS:

  • Maximum/minimum voltage
  • Maximum, minimum current or load absence and unbalance
  • Phase sequence, unbalance and failure
  • Dry run (choose between the following options):
    - Pressure (transducer);
    - Minimum current;
    - Cosφ;
    - Level (probes or floats)
  • Fuses or circuit breaker for power circuit protection
  • Electronic card protection fuses

SETTINGS AND CONTROLS:

  • Language
  • Mains return delay
  • Minimum voltage
  • Maximum voltage
  • Minimum current (dry run)
  • Maximum current (overload)
  • Phases unbalance
  • Dry run delay
  • Dry run reactivation delay
  • Dry run reactivation attempts number
  • Thermal delay
  • Thermal reactivation delay
  • Thermal reactivation attempts number
  • Minimum cosφ
  • Hour counter
  • Digital application selection (probes, floats, pressure switches)
  • Analog application selection (transducer):
    - Sensor type (pressure or level);
    - Sensor pressure;
    - Maximum pressure;
    - Dry run pressure;
    - Dry run delay;
    - Filling delay;
    - Discharge/filling mode;
    - Alarm level;
    - Minimum level;
    - Maximum level
  • Automatic reactivation mode
  • Autoconfiguration
  • Probes sensitivity: from 5 to 120 kΩ
 

PRODUCTS TYPOLOGY

ELECTRONIC DIRECT STARTERS

CATEGORY OF USE

AGRICULTURE
CIVIL USE
SEWAGE

TECHNOLOGY

ELECTRONIC

CABINET MATERIAL

ABS

CAPACITOR

NO

IGNITION TYPOLOGY

START-STOP PUSH BUTTONS
AUT-O-MAN PUSH BUTTONS

METERS

DIGITAL INSTRUMENT

PROTECTION

ELECTRONIC CARD

DOOR INTERLOCK SWITCH DISCONNECTOR

YES

PHASES

400V THREE PHASE – 400V THREE PHASE

NO. ENGINES

1

DISPLAY

LCD SCREEN

DRY RUNNING CONTROL

DRY RUNNING CONTROL WITH MINIMUM CURRENT
DRY RUNNING CONTROL THROUGH LEVEL PROBES

PRESSURE TRANSDUCER

YES

POWERS (HP)

0,5
0,75
1
1,5
2
3
4
5
5,5
7,5
10
12,5
15
17,5
20

WIRED ACCESSORIES (OPTIONAL)

ALARM CIRCUIT WITH FLASHING SIREN